The Well Groups view
The Well Groups section is used to describe well groups.
WellGroup tab
The Well Group tab allows you to define the group or groups of wells for a simulation. Groups can be put into subgroups and are connected with the parent.
Active When checked indicates that well is active. An inactive well is not written to the deck.
Name Name of the Well Group.
Parent Selects the parent using a combo box.
Definition Date Assigns a time step to the well group.
Group Configuration tab
The Group Configuration tab allows you to define various settings for each well group. The Group Configuration tab includes sorting functionality, similar to the sort functionality found in the Manual Data Select Tab for Production Data views. If you wish to sort the groups in the view you can drag one of the column headers to the green area above the table to sort by that header. For example, you could drag the Time column header to sort all groups by their start time.
Group Specify the group for the configuration.
Date/Time Enter the date and time for the group.
MANIFOLD Enable the manifold for the stream.
PCONMANIFOLD Indicates that the group surface pressure constraint will be translated to a tubing-head pressure constraint.
ONTIME The fraction of the time the group is on-line.
APPOR-METHOD Specify the apportionment method.
GFUELMAXR Enter the maximum fuel consumption rate.
GMKMAXR Specify the maximum surface make-up rate.
GPHYDDEP Specify the manifold depth for calculation pressure drop.
GPTABLE Enter the tubing table number between the manifold and the surface.
WMKUPTO Specify the water make-up target for the group.
WPRODGROUP Specify the group from which the water and total production rates will be taken for water recycling/voidage replacement calculation.
WRECYMAXR Enter the maximum make-up water rate.
Group Constraint tab
The Group Constraint tab allows you to define the constraints a well group will have. The production, injection and monitoring constraint (GCONP, GCONI, and GCONM respectively) types are defined in the Constraint column as well as GUIDEI and GUIDEP. Qualifiers, Types, and values are then filled depending on the options chosen.
Group Specify the group for which you want to define the constraints.
Date/Time Enter the date and time for the group.
Constraint For group constraints, GCONP, GCONI, and GCONM are available in this column. To specify guide rates, GUIDEP and GUIDEI can be selected. GAPPOR is available if you wish to apportion a group’s rate target. See the list of constraints below for more information.
Mat/Frac Only active if one of GCONP, GCONI, or GAPPOR is specified as the constraint. For each of these three constraints, a different set of options will be available in this column.
Type Specify the type (subkeyword) for the constraint. The set of options in this column is dependent upon the Constraint and Qualifier combination. See the following table for a description of each keyword found in this column.
Value Specify the value for the constraint.
Action Select the action for the constraint. The list of options in this column is dependent upon the selection in the Constraint and Qualifier columns.
STOP Indicates that the simulation should be stopped if the constraint is violated.
CONT Indicates that the simulation should continue, even if the constraint is violated.
SHUTMOW Indicates that the most offending layer in the most offending well should be shut if the GOR, WCUT, WGR, MAXGAS, or MAXSTW monitor is violated.
SHUTMOL Indicates that the most offending well should be shut if the GOR, WCUT, WGR, MAXGAS, or MAXSTW monitor is violated.
SHUTMOLDOWN Indicates that the most offending layer and all of the layers below it in the most offending well should be shut if the GOR, WCUT, WGR, MAXGAS, or MAXSTW monitor is violated.
SHUTMOLUP Indicates that the most offending layer and all of the layers above it in the most offending well should be shut if the GOR, WCUT, WGR, MAXGAS, or MAXSTW monitor is violated.
SHUTMOWS Indicates that a list of prioritized most offending wells (based on the wells with the great GOR, WCUT, or WGR) should be shut if the GOR, WCUT, WGR, MAXGAS, or MAXSTW monitor is violated.
SHUTALL Indicates that all currently open wells in the group will shut if the monitored constraint is violated.
Order Enter a value here for the order in which the constraint should be evaluated.
Constraints Subkeywords
BHF Specify the bottom hole fluid rate.
BHG Specify the reservoir gas rate.
BHW Specify the reservoir water rate.
CPP Specify a compressor pressure. Note that this constraint may only be applied if the group production is set as going through a manifold.
GAS Used to indicate the phase for the connected production wells when either the *PMAINT or *RECYCLE qualifier is selected.
GCP Specify the gas compressor pressure for injection. Note that the group must be defined as gas injection passing through a manifold.
GMKUP Used to indicate that the gas phase is the make-up stream supplemented to meet the total voidage replacement fraction.
GMP Specify the gas manifold pressure for injection. Note that the group must be defined as gas injection passing through a manifold.
MNP Specify the manifold pressure. Note that this constraint may only be applied if the group production is set as going through a manifold.
OFF Disables the AUTODRILL option, preventing any shut wells from opening for the purpose of supplementing the injection/production group in meeting its target.
ON Indicates that any shut well that may potentially contribute to the injection or production target may be opened if the apportionment routine finds that the contributing wells will fail to meet the target.
SCP Specify the solvent compressor pressure for injection. Note that the group must be defined as gas injection passing through a manifold.
SMKUP Used to indicate that the solvent phase is the make-up stream supplemented to meet the total voidage replacement fraction.
SMP Specify the solvent manifold pressure for injection. Note that the group must be defined as gas injection passing through a manifold.
SOLVENT Used to indicate the phase for the connected production wells when either the *PMAINT or *RECYCLE qualifier is selected.
STG Specify the surface gas rate.
STL Specify the total surface liquid rate (oil plus water).
STO Specify the surface oil rate.
STS Specify the surface solvent rate.
STW Specify the surface water rate.
WATER Used to indicate the phase for the connected production wells when either the *PMAINT or *RECYCLE qualifier is selected.
WCP Specify the water compressor pressure for injection. Note that the group must be defined as gas injection passing through a manifold.
WMKUP Used to indicate that the water phase is the make-up stream supplemented to meet the total voidage replacement fraction.
WMP Specify the water manifold pressure for injection. Note that the group must be defined as gas injection passing through a manifold.
Group Cycling tab
This tab is for use when running a simulation with alternating production and injection cycles. The Group Cycling tab consists of two sub-panels, Group Cycle Definition for specifying cycle settings, and Start/Stop Group Cycling for turning on and off the cycle and setting a start/stop date.
Group Cycling Definition
On this tab you can specify various options for the group cycle including basic cycling properties and cycle switching options. The main table in the view is dependent upon the selected group in the table in the left pane. Changes made to the definition in the main table only affect the active table.
Start/Stop Group Cycling